asecos Main catalogue - Working safely with hazardous substances

Order No. 39709 Technical data SAS Electronic housing W x D x H mm 90 x 75 x 45 Nominal frequency Hz 50/60 Nominal flow mA 100 Exhaust air volume flow m³/h 10-150 Order No. 14945 Model Description Order No. SAS for safety cabinets according to EN 14470-1 System for condition monitoring of the min. 10-fold air change with visual display, potential-free switching contact and external differential pressure measuring point 39709 SAS for under bench cabinets according to EN 14470-1 System for condition monitoring of the min. 10-fold air change with visual display, potential-free switching contact and external differential pressure measuring point 39710 SAS for gas cylinder cabinets in accordance with EN 14470-2 System for condition monitoring of the min. 10-fold air change with visual display, potential-free switching contact and external differential pressure measuring point 40174 APG.26.30-BL Exhaust air monitoring unit with exhaust air monitoring BASIC-LINE 14945 Technical data APG.26.30-BL External dimensions W x D x H mm 300 x 400 x 265 Max. current consumption A 0.15 Noise level (approx.) dB 28.0 Weight kg 10 Min. volume flow m³/h 30 356 Safety Assistance System SAS for permanent monitoring of safe and energy-efficient storage of hazardous substances • Maximum safety through permanent monitoring of the technical ventilation (explosion protection and protection of employee health) • High energy efficiency thanks to control of extract air demand according to technical necessity • For safety cabinets according to EN 14470-1 as well as gas cylinder cabinets according to EN 14470-2 • Can be installed ex works or retrofitted in existing safety cabinets • Permanent detection of the exhaust air volume flow by integrated differential pressure measurement with electronic evaluation • Visual alarm when the minimum exhaust air volume flow is not reached and when doors or pull-outs are not fully closed • Potential-free alarm contact for central monitoring • Battery back-up in case of power failure (optional) • Measuring connection for targeted setting of an energy-efficient extract air volume flow rate Exhaust air monitoring systems Exhaust air monitoring systems – quick installation for a safe and reliable monitoring of the exhaust air • Electro-pneumatic air exhaust monitoring • Minimum volume flow 30 m³/h • With connection cable (3 m) and power cord • Mounting between cabinet and on-site air exhaust-system • Connecting fitting DN 75 • Ready to plug-in, quick installation • ATEX compliant: C` II 3/-G Ex n llC T4

RkJQdWJsaXNoZXIy NzIzNDY=