asecos Main catalogue - Working safely with hazardous substances

380 GAP.140.120.WA GAP.140.120.WA 40589-901 support frame as weighing rack with granite block for seated activities (panel melamine resin-coated) electrical component preinstalled outlet with cable duct integrated in media duct or media slot working surface with cutout 400x400mm (stainless steel brush-finished) socket(s) 1 pair 230 V, IP54, up to 16A integrated in media duct or media slot aluminium base (aluminium anodised) Model with the following components Order No. GAP.140.090.WA 40584-901 support frame as weighing rack with granite block for seated activities (panel melamine resin-coated) electrical component preinstalled outlet with cable duct integrated in media duct or media slot working surface with cutout 400x400mm (stainless steel brush-finished) socket(s) 1 pair 230 V, IP54, up to 16A integrated in media duct or media slot aluminium base (aluminium anodised) GAP-LINE | Weighing work stations Weighing work stations with testing of the air equipment according to EN 14175-3 (5.4.4) Function / construction: • Required occupational exposure limits are maintained • Avoidance of dangerous explosive atmosphere • Testing of the air equipment according to EN 14175 Part 3 (5.4.4) • Optimised for technical ventilation - particularly economical • Savings of >20% of the exhaust air volume compared to similar units • Height of engagement 830 mm, front panel PMMA (transparent acrylic glass) • Robust construction made of chemically resistant, anodised aluminium profiles • Weighed materials are not scattered by the fresh air curtain at the front • Vibration-free facility for mounting the analytical scales on a granite block decoupled from the hazardous material work station • Usable for analytical scales with a measuring range of up to 0,00001 g • Highly effective capturing of hazardous materials inside the work station through special fresh air curtain technology • Prepared for connection to the on-site exhaust air system and for electrical supply (230 V/50 Hz) Standard equipment • Monitoring electronics incl. potential-free switching contact, e.g. for controlling on-site exhaust air system • Workplace light • Fold-away deflector • Melamine resin coated rear wall • Electrical connection socket (230 V) on the roof • Preinstalled empty socket incl. empty conduit for data cable • 2 sockets (230 V / 50 Hz) • Transparent side walls • Work surface made of brushed stainless steel • Support frame for sitting work with decoupled granite block, cutout 400 x 400 mm

RkJQdWJsaXNoZXIy NzIzNDY=